MOTOR PROTECTION RELAYS (MPR)
|
E1 Plus Electronic Overload Relays - 193 - ED |
|
|
• Rated Current (Range) |
: |
0.1...27 A |
• NEMA Operating Voltage, Nominal |
: |
|
• IEC Operating Voltage, Nominal |
: |
690 V |
• Overload Type |
: |
Solid - State |
• Trip Class (Fixed) |
|
10 |
• Trip Class (Adjustable) |
: |
|
• Reset Type |
|
|
• Ambient Temperature Compensated |
|
Manual only |
• Adjustment Range |
: |
5:1 |
• Phase Loss |
: |
3 s |
• Ground (Earth) Fault |
: |
|
• Overcurrent (Jam) Detection |
: |
|
• Stall Detection |
: |
|
• Underload Detection |
: |
|
• Current Imbalance |
: |
|
• PTC Thermistor Monitoring |
: |
|
• Warning Settings |
: |
|
• N.C.Trip Contact |
: |
|
• N.O. Alarm Contact |
: |
|
• No. of Outputs |
: |
|
• No. of Inputs |
: |
|
• ODVA (DeviceNet) Conformance |
: |
|
• Variable Frequency Drive (VFD) |
: |
|
| |
|
|
|
|
|
| |
|
|
|
| |
|
E1 Plus Electronic Overload Relay - 193/592-EE
|
|
|
• Rated Current (Range) |
: |
0.1...800 A |
• NEMA Operating Voltage, Nominal |
: |
600 A |
• IEC Operating Voltage, Nominal |
: |
690/1000 V |
• Overload Type |
: |
Solid - State |
• Trip Class (Fixed) |
|
|
• Trip Class (Adjustable) |
: |
10, 15, 20, 30 |
• Reset Type |
|
|
• Ambient Temperature Compensated |
|
Automatic and Manual |
• Adjustment Range |
: |
5:1 |
• Phase Loss |
: |
3 s |
• Ground (Earth) Fault |
: |
Optional |
• Overcurrent (Jam) Detection |
: |
Optional |
• Stall Detection |
: |
|
• Underload Detection |
: |
|
• Current Imbalance |
: |
|
• PTC Thermistor Monitoring |
: |
Optional |
• Warning Settings |
: |
|
• N.C.Trip Contact |
: |
|
• N.O. Alarm Contact |
: |
|
• No. of Outputs |
: |
|
• No. of Inputs |
: |
|
• ODVA (DeviceNet) Conformance |
: |
Optional |
• Variable Frequency Drive (VFD) |
: |
|
|
|
| |
|
|
| |
|
|
|
| |
|
E3 Electronic Overload Relay - 193/592-EC1
|
|
|
• Rated Current (Range) |
: |
0.1...5000 A |
• NEMA Operating Voltage, Nominal |
: |
600 A |
• IEC Operating Voltage, Nominal |
: |
690/1000 V |
• Overload Type |
: |
Microprocessor - Based |
• Trip Class (Fixed) |
|
|
• Trip Class (Adjustable) |
: |
5...30 |
• Reset Type |
|
|
• Ambient Temperature Compensated |
|
Automatic and Manual |
• Adjustment Range |
: |
5:1 |
• Phase Loss |
: |
Adjustable Relay |
• Ground (Earth) Fault |
: |
|
• Overcurrent (Jam) Detection |
: |
|
• Stall Detection |
: |
|
• Underload Detection |
: |
|
• Current Imbalance |
: |
|
• PTC Thermistor Monitoring |
: |
|
• Warning Settings |
: |
|
• N.C.Trip Contact |
: |
|
• N.O. Alarm Contact |
: |
|
• No. of Outputs |
: |
1 |
• No. of Inputs |
: |
2 |
• ODVA (DeviceNet) Conformance |
: |
|
• Variable Frequency Drive (VFD) |
: |
|
|
|
| |
|
|
| |
|
|
 |
| |
|
E3 Electronic Overload Relay - 193/592-EC2/EC3
|
|
|
• Rated Current (Range) |
: |
0.4...5000 A |
• NEMA Operating Voltage, Nominal |
: |
600 A |
• IEC Operating Voltage, Nominal |
: |
690/1000 V |
• Overload Type |
: |
Microprocessor - Based |
• Trip Class (Fixed) |
|
|
• Trip Class (Adjustable) |
: |
5...30 |
• Reset Type |
|
|
• Ambient Temperature Compensated |
|
Automatic and Manual |
• Adjustment Range |
: |
5:1 |
• Phase Loss |
: |
Adjustable Relay |
• Ground (Earth) Fault |
: |
Sensitive |
• Overcurrent (Jam) Detection |
: |
|
• Stall Detection |
: |
|
• Underload Detection |
: |
|
• Current Imbalance |
: |
|
• PTC Thermistor Monitoring |
: |
|
• Warning Settings |
: |
|
• N.C.Trip Contact |
: |
|
• N.O. Alarm Contact |
: |
|
• No. of Outputs |
: |
2 |
• No. of Inputs |
: |
4 |
• ODVA (DeviceNet) Conformance |
: |
|
• Variable Frequency Drive (VFD) |
: |
|
|
|
|
| |